Isolating a Weed-Loaded Bottom Wire With a Cut-Out Switch and a Fault Finder: Current Before and After the Switch, the 3 kV Floor, and When to Leave the Bottom Wire Off
Disclosure: This post contains affiliate links. If you purchase through these links, we may earn a small commission at no extra cost to you.
In late summer, the bottom wire of an electric fence often runs through a strip of grass and weeds that bleeds current into the ground. A fault finder that reads current shows exactly how much of the energizer's output that one wire is losing. A cut-out switch on the bottom wire lets you prove it in seconds and shut it off until the strip is mowed.
How do you tell if weeds on the bottom wire are draining an electric fence?
Read the current on each hot wire with a fault finder, then open the bottom wire's cut-out switch and read again. If the total current falls sharply and the fence voltage climbs back toward normal, the vegetation on that bottom wire was the load. Mow or trim, then reconnect.
Virginia Cooperative Extension's Troubleshooting Electric Fences (SPES-692) notes that soil moisture or a vegetation load can make fence voltage swing through the year. It recommends at least 3,000 to 5,000 volts for cattle or 7,000 volts for sheep. It also suggests using cutout switches to isolate and test smaller areas, including one that removes power from the bottom wire during heavy grass loads.
The same bulletin says fault finders read amps as well as volts, often with an arrow pointing toward the fault. A low-volt, high-amp reading in one section followed by high volts and low amps in the next means you've passed the fault.
Gallagher's Power Fence Systems user manual lists vegetation with faulty insulation and accidental shorts as causes of a shorted fence. It says to check the fence when it drops below 3,000 V (3 kV) and to isolate different fences at junctions with a cut-out switch. Its energizer distance chart warns that the distance may need to be reduced in high-vegetation areas.
Reading the Before-and-After Numbers
| Check | Weed load | Something else |
|---|---|---|
| Bottom wire current | Highest of all wires | Similar to others |
| Switch opened | Total current drops | Little change |
| Voltage after opening | Rises toward normal | Stays low |
| Next step | Mow the strip | Walk with the arrow |
On a fence with its wires joined in parallel, the current on each wire adds up to the total. Write all of them down before you touch the switch, so the comparison is real and not from memory.
Where the Bottom-Wire Switch Goes
- At the energizer end: place the switch on the jumper that feeds the bottom wire from the wire above, so one handle cuts only that wire
- At a gateway: place a second switch where the undergate cable joins, to isolate the far section
- Labeled: mark which wire each switch feeds on the post beside it
- Reachable: mount at chest height on a post you pass every day
Materials and Tools
- Electric fence fault finder that reads voltage and current with a direction arrow
- A cut-out switch rated for electric fences, plus insulated jumper wire and joint clamps
- A string trimmer or mower for the fence strip
- Insulated gloves and fence pliers
- A notebook for the readings
Weed-Load Steps
- Read the voltage. Check the fence well away from the energizer and note whether it is below 3 kV.
- Read each wire. Put each hot wire through the fault finder's slot near the energizer and log the current.
- Open the bottom switch. Flip the bottom-wire cut-out switch off.
- Read again. Re-check the total current and the voltage at the same spots.
- Compare. A large drop in current with a rise in voltage points to the bottom wire's vegetation.
- Power down to work. Turn off the energizer before trimming close to any wire.
- Clear the strip. Mow or trim under the bottom wire along the full run.
- Reconnect and confirm. Close the switch, power up, and check that the bottom wire's current is back near the other wires.
Weed-Strip Safety
- Turn off the energizer before trimming within reach of the wires, and keep it off until you're clear
- Never use a metal-bladed trimmer against a live wire
- Remember that a switched-off bottom wire leaves a gap that small animals can use
- Don't work on the fence during thunderstorms
Testing strands one by one on a taller fence is covered in testing a 5-wire polywire deer fence. Grass loads on netting are covered in testing 164-foot electric netting around a garden.
If voltage stays low after the weeds are cleared, check the earth side with testing ground rods on a garden electric fence. Where the bottom wire guards a run or coop wall, choose the wall mesh from the hardware cloth mesh size and gauge guide.
FAQ
Can I leave the bottom wire switched off all summer?
You can during heavy growth, as Virginia Extension suggests, but the fence loses its lowest barrier. If raccoons or rabbits are the reason for that wire, keep the strip mowed and keep it on.
Why does the voltage drop more after rain?
Wet weeds conduct more current to the ground. Recheck the bottom wire after a rain and before mowing.

Comments
Post a Comment